[PATCH] can: mcba_usb: Fix termination command argument

From: Yasushi SHOJI
Date: Wed Nov 23 2022 - 14:44:38 EST


Microchip USB Analyzer can be set with termination setting ON or OFF.
As I've observed, both with my oscilloscope and USB packet capture
below, you must send "0" to turn it ON, and "1" to turn it OFF.

Reverse the argument value to fix this.

These are the two commands sequence, ON then OFF.

> No. Time Source Destination Protocol Length Info
> 1 0.000000 host 1.3.1 USB 46 URB_BULK out
>
> Frame 1: 46 bytes on wire (368 bits), 46 bytes captured (368 bits)
> USB URB
> Leftover Capture Data: a80000000000000000000000000000000000a8
>
> No. Time Source Destination Protocol Length Info
> 2 4.372547 host 1.3.1 USB 46 URB_BULK out
>
> Frame 2: 46 bytes on wire (368 bits), 46 bytes captured (368 bits)
> USB URB
> Leftover Capture Data: a80100000000000000000000000000000000a9

Signed-off-by: Yasushi SHOJI <yashi@xxxxxxxxxxxxxxx>
---
drivers/net/can/usb/mcba_usb.c | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/net/can/usb/mcba_usb.c b/drivers/net/can/usb/mcba_usb.c
index 218b098b261d..67beff1a3876 100644
--- a/drivers/net/can/usb/mcba_usb.c
+++ b/drivers/net/can/usb/mcba_usb.c
@@ -785,9 +785,9 @@ static int mcba_set_termination(struct net_device *netdev, u16 term)
};

if (term == MCBA_TERMINATION_ENABLED)
- usb_msg.termination = 1;
- else
usb_msg.termination = 0;
+ else
+ usb_msg.termination = 1;

mcba_usb_xmit_cmd(priv, (struct mcba_usb_msg *)&usb_msg);

--
2.38.1